engine: 3.5 petrol,
control unit: Visteon EEC-VI KMDF7J9.H32,
software version: DB5A-14C204-GJ,
in the firmware, the control of catalysts (Euro 2) and lower lambda probes is disabled. You can remove the connectors from the lower oxygen sensors. The firmware in the PCM Flash.